The
HMI 118 Series Excess Flow Ball Check Valve has a free
floating ball, no spring. It was designed for use in a
vertical position with a vertical flow. These valves are
not positive sealing and will weep when closed so the
valve will reset automatically. The smaller sizes are
ideal for mounting pressure gages.
This
valve can be used as a back pressure ball check valve and
can be used in any position when the flow is reversed.
The HMI 119 Series Back Pressure Ball Check Valve would
be a better choice as they are positive closing valves.
The 118 Series Excess Flow Ball Check Valves should only